Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: A consensus document from the Tunisian Society of Oncology Radiotherapy and the Tunisian Society of Cardiology and Cardiovascular Surgery

##plugins.themes.academic_pro.article.main##

Samia Zarraa
Fatma Dhouib
Afef Ben Halima
Sana Ouali
Rim Moujahed
Sameh Tebra
Zeyneb Jabbari
Jamel Yahyaoui
Wissal Jbara
Mounir Besbes
Chiraz Nasr
Asma Belaïd
Jamel Daoued
Lilia Zakhama
Lotfi Kochbati

Abstract

In patients with cardiac implantable electronic devices CIEDs, including cardiac pacemakers (PM) and implantable cardioverter-defibrillators (ICD), radiotherapy (RT) could compromise CIED function.
Managing radiotherapy patients with CIED, has been a great practical and procedural challenge in radiotherapy and requires a structured multidisciplinary approach.
A consensus document is presented as a result of a multidisciplinary working group involving cardiac electrophysiologists, Radiation Oncologists and Medical physicists.
It aims to propose recommendations on risk stratification, management approach before, during and after radiation treatment/course of patients with CIED.

Keywords:

cardiac implantable electronic devices (CIED), device malfunction, pacemakers (PM), implantable cardioverter-defibrillators (ICD), patient management, radiotherapy, cancer

##plugins.themes.academic_pro.article.details##

References

  1. 1. Mond HG, Irwin M, Ector H, Proclemer A. The world survey of cardiac pacing and cardioverter-defibrillators: calendar year 2005 an International Cardiac Pacing and Electrophysiology Society (ICPES) project. Pacing Clin Electrophysiol. 2008;31:1202-1212. 2. Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC) Developed in collaboration with the European Heart Rhythm Association (EHRA) Eur Heart J. 2013;34:2281-2329. 3. Delaney G, Jacob S, Featherstone C, Barton M. The role of radiotherapy in cancer treatment: estimating optimal utilization from a review of evidence-based clinical guidelines. Cancer. 2005 Sep 15;104(6):1129-37. 4. Miften M, Mihailidis D, Kry SF et al. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: A report of the AAPM TG-203. Med Phys 2019;46:e757-e88 5. Bernstein AD, Daubert JC, Fletcher RD, Hayes DL, Lüderitz B, Reynolds DW, Schoenfeld MH, Sutton R. The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing. North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group. Pacing Clin Electrophysiol. 2002 Feb;25(2):260-4. 6. Bitterman DS, Zei PC, Mak RH. Radiation Safety and Cardiovascular Implantable Electronic Devices Int J Radiat Oncol Biol Phys 2018 Oct 1;102(2):243-246. 7. Yeung C, Chacko S, Glover B, Campbell D, Crystal E, Ben-Dov N, Baranchuk A, Radiotherapy for Patients with Cardiovascular Implantable Electronic Devices: A Review, Can J Cardiol. 2018;34(3):244-251 8. Indik JH, Gimbel JR, Abe H, Alkmim-Teixeira R, Birgersdotter- Green U, Clarke GD, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm. 2017; 14(7):e97-e153. 9. Brambatti M, Mathew R, Strang B, et al. Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy. Heart Rhythm 2015;12(10):2148-2154. 10. Grant JD, Jensen GL, Tang C, et al. Radiotherapy-induced malfunction in contemporary cardiovascular implantable electronic devices: clinical incidence and predictors. JAMA Oncol 2015;1(5):624-632. 105. 11. Makkar A, Prisciandaro J, Agarwal S, et al. Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function. Heart Rhythm 2012;9(12):1964-1968. 12. Zaremba T, Jakobsen AR, Sogaard M, et al. Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a populationbased cohort study. Pacing Clin Electrophysiol 2015;38(3):343-356. 13. Kazuhiko Nakamura, Takahiro Aoyama, Naoki Kaneda, Masashi Otsuji, Yoshitaka Minami, Ami Sakuragi, Masaru Nakamura. Effect of X-ray dose rates higher than 8 Gy/min on the functioning of cardiac implantable electronic devices. J Radiat Res. 2020 May; 61(3): 419-425. 14. Ohno T, Soejima T, Sekiguchi Y, Hashimoto T, Koike I, Matsubara H, et al. JASTRO/JCS Guidelines for radiotherapy in patients with cardiac implantable electronic devices. J Radiat R. 2021;62(1):172-184. 15. Michael Glikson, Jens Cosedis Nielsen, Mads Brix Kronborg, Yoav Michowitz, Angelo Auricchio. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: supplementary data. European Heart Journal. 202 ; 00, 1-32 16. Huertas A, Thuillot M, Bibault J-E, Sharifzadehgan Laurans A, Giraud P, et al. Prise en charge des patients porteurs de stimulateurs cardiaques ou défibrillateurs automatiques implantables traités par irradiation. Cancer Radiother (2018). 17. Zecchin M, Severgnini M, Fiorentino A, Malavasi VL, Menegotti L, Alongi F, et al. Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: A consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM). Int J Cardiol. 2018; 255:175-183. 18. Grant JD, Jensen GL, Tang C, Pollard JM, Kry SF, Krishnan S, et al. Radiotherapy-induced malfunction in contemporary cardiovascular implantable electronic devices: clinical incidence and predictors. JAMA Oncol. 2015;1(5):624-32. 19. Gossman MS, Wilkinson JD, Mallick A. Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: retrospective physician surveys including chart reviews at numerous centers. Med Dosim. 2014;39(4):320-4. 20. SungW, Kim S, Kim JI, Lee JG, Shin YJ, Jung JY, et al. Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite((R)) treatment. Med Phys. 2012;39(10):6185-91. 21. Peet SC,Wilks R, Kairn T, Crowe SB. Measuring dose from radiotherapytreatments in the vicinity of a cardiac pacemaker. Phys Med. 2016;32(12):1529-36. 22. Wadasadawala T, Pandey A, Agarwal JP, Jalali R, Laskar SG, Chowdhary S, et al. Radiation therapy with implanted cardiac pacemaker devices: a clinical and dosimetric analysis of patients and proposed precautions. Clin Oncol (R Coll Radiol). 2011;23(2):79-85. 23. Makkar A, Prisciandaro J, Agarwal S, Lusk M, Horwood L,Moran J, et al. Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function. Heart Rhythm. 2012;9(12):1964-8. 24. Munshi A, Agarwal JP, Pandey KC. Cancer patients with cardiac pacemakers needing radiation treatment: a systematic review. J Cancer Res Ther. 2013;9(2):193-8. 25. Gauter-Fleckenstein B, Israel CW, Dorenkamp M, Dunst J, Roser M, Schimpf R,et al. DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlenther Onkol Organ Dtsch RontgengesellschaftAl 2015;191:393-404. 26. Barillot I, Mazeron R, Mornex F, Giraud P. Patients porteurs d'un stimulateur cardiaque ou d'un défibrillateur implantable. Cancer Radiother2016;20:S256-8. 27. Sharifzadehgan A , Laurans M, Thuillot M , Huertas A, Baudinaud P, Mirabel M, Bibault JE, et al. Radiotherapy in Patients with a Cardiac Implantable Electronic Device. Am J Cardiol. 2020;128:196-201.