Abstract
Introduction: Congenital heart defects are the most common congenital malformations in the newborn with an estimated incidence ranging between 6-9 ‰. In Tunisia, this incidence reaches 1.9 ‰. This can be explained by misdiagnosed cases. In fact, the diagnosis is based mainly on clinical examination which allows making the diagnosis only in 50 in 75 % of the cases. Several studies showed the interest of pulse oximetry oximeter in the screening of cyanogenic and duct dependent congenital heart diseases. The objective of our work is to determine the incidence of congenital heart diseases screened by physical examination coupled with the measure of transcutaneous saturation
Methods:  forward-looking and descriptive Study, concerning all the births of the central maternity of Sousse, during a period of 12 months. We have measured transcutaneous saturation of all the newborn children in association to routine physical, examination. This study aimed to screen congenital heart disease and then calculate their incidence.
Results: during the period of the study 10447 newborn children had been born in the central maternity of Sousse. Among whom, 26 had a congenital heart defect. The incidence of the neonatal cardiac malformations in our current study was found in 2.77 ‰ of alive births. It was about 1.1 ‰ of newborns in a similar study practised in 2009 (Chi2=76.2 et p<10-4). The heart disorder was diagnosed following the grip taking of the only percutaneous saturation in 5 newborn children and following the clinical examination in 21.
Conclusion: the measure of the transcutaneous saturation in the first day of life is a little expensive and specific method for the early screening of the duct dependent cardiac malformations.

Keywords:

Congenital cardiopathy, Newborn, pulse oximetry, screening, incidence.

##plugins.themes.academic_pro.article.details##

References

  1. Hoffmann JIE, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002; 39(12):1890-900.
  2. Methlouthi J, Mahdhaoui N, Mougou S, Ghannem S, Bellaleh M, Ayech H, et al. Epidémiologie des cardiopathies congénitales diagnostiquées à la période néonatale. Revue Tunisienne de Cardiologie 2015; II(2) :102-7.
  3. Khrouf N, Ben Miled S, Moussaoui M, Chibani M, Sprung G. Les malformations observées chez le nouveau-né. Etude prospective portant sur dix mille naissances. Tunisie médicale. 1985;63:289-90.
  4. Arlettaz R, Bauschatz AS, Mönkhoff M, Essers B, Bauersfeld U. The contribution of pulse oximetry to the early detection of congenital heart disease in newborn. Eur J Pediatr. 2005; 165(2):94-8.
  5. De-Wahl Granelli A, Wennergren M, Sandberg K, Mellander M, Bejlum C, Inganäs L, et al. Impact of pulse oximetry screening on the detection of duct dependant congenital heart disease: a Swedish prespective screening study in 39821 newborn. BMJ. 2009; 338:a3037.
  6. Ewer AK, Furmston AT, Middleton LJ, Deeks JJ, Daniels JP, Pattison HM, et al. Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness. Health technol Assess Winch Engl. 2012;16(2):1-184.
  7. Mahle WT, Newburger JW, Matherne GP, Smith FC, Hoke TR, Koppler R, et al. Role of pulse oximetry in examining newborn for congenital heart disease: a scientific statement from the American heart association and American academy of pediatrics. Circulation. 2009; 120(5):447-58.
  8. Robert-Gnansia E, Francannet C, Bozio A, Bouvagnet P. Epidemiologie, Etiologie et genetique des cardiopathies congenitales. EMC-Cardiologie Angéiologie 1 (2004) 140-160.
  9. Gournay V. dépistage des cardiopathies congénitales graves par oxymétrie de pouls en maternité chez des nouveau-nés asymptomatiques. Arch Pédiatrie. 2015 ; 22(5) :75-6.
  10. Aamir T, Kruse L, Ezeakudo O. delayed diagnosis of critical congenital cardiovascular malformations (CCVM) and pulse oximetry screening of newborn. Acta paediatr (Oslo, Norway: 1992) 2007; 96 (8): 1146-9.
  11. Tabin R. Pédiatrie: Améliorer le dépistage et la prise en charge des cardiopathies congénitales. Forum Med Suisse 2006; 6:31-32.
  12. Turska Kmieć A, Borszewska Kornacka MK, Błaż W, Kawalec W, Zuk M. Early screening for critical congenital heart defects in asymptomatic newborns in Mazovia province: experience of the POLKARD pulse oximetry programme 2006-2008 in Poland. Kardiol Pol. 2012; 70(4):370-6.
  13. Ewer AK. Pulse oximetry screening for critical congenital heart defects in newborn infants: should it be routine? Arch Dis Child Fetal Neonatal. 2014; 99(1):F93-5.
  14. Harden BW, Martin GR, Bradshaw EA. False-negative pulse oximetry screening for critical congenital heart disease: the case for parent education. Pediatr Cardiol. 2013; 34(7):1736-8
  15. Zhao Q, Ma X, Ge X, Liu F, Yan W, Wu L, et al. Pulse oximetry with clinical assessment to screen for congenital heart disease in neonates in China: a prospective study. Lancet Lond Engl. 2014; 384(9945):747-54.
  16. Ewer AK, Middleton LJ, Furmston AT, Bhoyar A, Daniels JP, Thangaratinam S, et al. Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study. The Lancet. 2011; 378(9793):785-94.